3SU1150-1HA20-3PH0
EM. STOP MUSHROOM PUSHBUTTON, 40MM, RED

From SIEMENS

EMERGENCY STOP mushroom pushbutton, 22 mm, round, metal, shiny, red, 40 mm, positive latching, acc. to EN ISO 13850, pull-to-unlatch mechanism, with yellow backing plate, inscription: EMERGENCY STOP, with holder, 1 NC, 1 NC, spring-type terminal
Product brand nameSIRIUS ACT
Product designationEMERGENCY STOP mushroom pushbuttons
Design of the productComplete unit
Product type designation3SU1
Manufacturer's article number
1 of supplied contact module
2 of supplied contact module
of the supplied holder
of the supplied actuator
of supplied accessory
Enclosure
Number of command points1
Actuator
Design of the operating mechanismpositive latching
Manner of function of the actuating elementLatching
Product extension optional Light sourceNo
Color
of the actuating elementRed
Material of the actuating elementplastic
Shape of the actuating elementround
Outer diameter of the actuating element40 mm
Number of contact modules2
Type of unlocking devicepull-to-unlatch mechanism
Front ring
Product component front ringNo
Holder
Material of the holderMetal
Display
Number of LED modules0
General technical data
Product function
positive openingYes
EMERGENCY OFF functionYes
EMERGENCY STOP functionYes
Product component
Light sourceNo
Insulation voltage
rated value500 V
Degree of pollution3
Type of voltage
of the operating voltageAC/DC
Surge voltage resistance rated value6 kV
Protection class IPIP66, IP67, IP69(IP69K)
of the terminalIP20
Degree of protection NEMA ratingNEMA 1, 2, 3, 3R, 4, 4X, 12, 13
Shock resistance
acc. to IEC 60068-2-27Sinusoidal half-wave 50 g / 11 ms
Operating frequency maximum600 1/h
Mechanical service life (switching cycles)
typical300 000
Electrical endurance (switching cycles)
typical300 000
Thermal current10 A
Reference code acc. to DIN EN 81346-2S
Reference code acc. to DIN EN 61346-2S
Continuous current of the C characteristic MCB10 A; for a short-circuit current smaller than 400 A
Continuous current of the quick DIAZED fuse link10 A
Continuous current of the DIAZED fuse link gG10 A
Operating voltage
at AC
— at 50 Hz rated value5 ... 500 V
— at 60 Hz rated value5 ... 500 V
at DC
— rated value5 ... 500 V
Power Electronics
Contact reliabilityOne maloperation per 100 million (17 V, 5 mA), one maloperation per 10 million (5 V, 1 mA)
Auxiliary circuit
Design of the contact of auxiliary contactsSilver alloy
Number of NC contacts for auxiliary contacts2
Number of NO contacts for auxiliary contacts0
Number of CO contacts
for auxiliary contacts0
Connections/Terminals
Type of electrical connection
of modules and accessoriesSpring-type terminal
Type of connectable conductor cross-sections
solid without core end processing2x (0.25 ... 1.5 mm²)
finely stranded with core end processing2x (0.25 ... 0.75 mm²)
finely stranded without core end processing2x (0.25 ... 1.5 mm²)
at AWG conductors2x (24 ... 16)
Tightening torque of the screws in the bracket1 ... 1.2 N·m
Safety related data
B10 value
with high demand rate acc. to SN 31920100 000
Proportion of dangerous failures
with low demand rate acc. to SN 3192020 %
with high demand rate acc. to SN 3192020 %
Failure rate [FIT]
with low demand rate acc. to SN 31920100 FIT
T1 value for proof test interval or service life acc. to IEC 6150820 y
Ambient conditions
Ambient temperature
during operation-25 ... +70 °C
during storage-40 ... +80 °C
Environmental category during operation acc. to IEC 607213M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95 %, no condensation in operation permitted for all devices behind front panel)
Installation/ mounting/ dimensions
Mounting typefront mounting
of modules and accessoriesFront plate mounting
Height40 mm
Width30 mm
Shape of the installation openinground
Mounting diameter22.3 mm
Positive tolerance of installation diameter0.4 mm
Mounting height46.4 mm
Installation width75 mm
Installation depth48.6 mm
Accessories
Number of backing plates1
Marking of backing plateEMERGENCY-STOP
Color of backing plateYellow

External links