| SIPLUS HMI KP300 Basic mono "3,6"" T1 RAIL -25 ... +55°C T1" at 70°C for 10 min with conformal coating based on 6AV6647-0AH11-3AX0 . Basic "Panel, key operation, 3"" FSTN" LCD display, Black/white, PROFINET interface, configurable from WinCE Basic V11/ STEP 7 Basic V11, contains open source software, which is provided free of charge See enclosed CD-ROM |
General information |
Product type designation | KP300 Basic mono PN |
Display |
Design of display | FSTN |
Screen diagonal | 3.6 in |
Display width | 87 mm |
Display height | 31 mm |
Number of colors | 4; Backlit display only (white, red, green, yellow) |
Resolution (pixels) |
Horizontal image resolution | 240 Pixel |
Vertical image resolution | 80 Pixel |
Backlighting |
MTBF backlighting (at 25 °C) | 50 000 h |
Backlight dimmable | No |
Control elements |
Keyboard fonts |
Function keys | |
— Number of function keys | 10 |
Keys with LED | No |
System keys | Yes |
Numeric keyboard | Yes; Keyboard |
alphanumeric keyboard | Yes; Keyboard |
Touch operation |
Design as touch screen | No |
Installation type/mounting |
Mounting position | vertical |
Mounting in portrait format possible | No |
Mounting in landscape format possible | Yes |
maximum permissible angle of inclination without external ventilation | 35° |
Supply voltage |
Type of supply voltage | DC |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Input current |
Current consumption (rated value) | 0.1 A |
Starting current inrush I²t | 0.5 A²·s |
Power |
Active power input, typ. | 3 W |
Memory |
Flash | Yes |
RAM | Yes |
Memory available for user data | 1 Mbyte |
Type of output |
Acoustics | |
Buzzer | No |
Speaker | No |
Time of day |
Clock |
Hardware clock (real-time) | No |
Software clock | Yes |
retentive | No |
synchronizable | Yes |
Interfaces |
Number of industrial Ethernet interfaces | 1 |
Number of RS 485 interfaces | 0 |
Number of RS 422 interfaces | 0 |
Number of RS 232 interfaces | 0 |
Number of USB interfaces | 0 |
Number of 20 mA interfaces (TTY) | 0 |
Number of parallel interfaces | 0 |
Number of other interfaces | 0 |
Number of SD card slots | 0 |
With software interfaces | No |
Industrial Ethernet |
Industrial Ethernet status LED | 2 |
Protocols |
PROFINET | Yes |
Supports protocol for PROFINET IO | No |
IRT | No |
PROFIBUS | No |
MPI | No |
Protocols (Ethernet) |
TCP/IP | Yes |
DHCP | Yes |
SNMP | Yes |
DCP | Yes |
LLDP | Yes |
WEB characteristics |
HTTP | No |
HTML | No |
Further protocols |
CAN | No |
EtherNet/IP | Yes |
MODBUS | Yes; Modicon (MODBUS TCP/IP) |
Interrupts/diagnostics/status information |
Diagnostic messages |
Diagnostic information readable | No |
Isolation |
Isolation tested with | 707 V DC (type test) and according to EN 50155 (routine test) |
Degree and class of protection |
IP (at the front) | IP65 |
Enclosure Type 4 at the front | Yes |
Enclosure Type 4x at the front | Yes |
IP (rear) | IP20 |
Standards, approvals, certificates |
Railway application |
EN 50121-3-2 | Yes; EMC for rail vehicles |
EN 50121-4 | Yes; EMC for signal and telecommunications systems |
EN 50124-1 | Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
EN 50155 | Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2 |
EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
Fire protection acc. to EN 45545-2 | Yes; Rail vehicles - verification on request |
Ambient conditions |
Ambient temperature during storage/transportation |
min. | -20 °C |
max. | 60 °C |
Altitude during operation relating to sea level |
Installation altitude above sea level, max. | 2 000 m |
Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
Relative humidity |
With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance |
Coolants and lubricants |
— Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
Use in stationary industrial systems |
— to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
— to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
— to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
Use on land craft, rail vehicles and special-purpose vehicles |
— to biologically active substances according to EN 60721-3-5 | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
— to chemically active substances according to EN 60721-3-5 | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); * |
— to mechanically active substances according to EN 60721-3-5 | Yes; Class 5S3 incl. sand, dust; * |
Remark |
— Note regarding classification of environmental conditions acc. to EN 60721 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
Conformal coating |
Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high availability |
Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Operating systems |
proprietary | Yes |
pre-installed operating system |
Windows CE | No |
Configuration |
Message indicator | Yes |
Alarm system (incl. buffer and acknowledgment) | Yes |
Process value display (output) | Yes |
Process value default (input) possible | Yes |
Recipe management | Yes |
Configuration software |
STEP 7 Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) |
STEP 7 Professional (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) |
WinCC flexible Compact | No |
WinCC flexible Standard | No |
WinCC flexible Advanced | No |
WinCC Basic (TIA Portal) | Yes |
WinCC Comfort (TIA Portal) | Yes |
WinCC Advanced (TIA Portal) | Yes |
WinCC Professional (TIA Portal) | Yes |
Languages |
Online languages |
Number of online/runtime languages | 5 |
Project languages |
Languages per project | 32 |
Functionality under WinCC (TIA Portal) |
Libraries | Yes |
Task planner | |
time-controlled | No |
task-controlled | Yes |
Help system | Yes |
Number of characters per info text | 320 |
Message system |
Number of alarm classes | 32 |
Bit messages | |
— Number of bit messages | 200 |
Analog messages | |
— Number of analog messages | 15 |
System messages HMI | Yes |
Number of characters per message | 80 |
Number of process values per message | 8 |
Message indicator | Yes |
Message buffer | |
— Number of entries | 256 |
— Circulating buffer | Yes |
— retentive | Yes |
— maintenance-free | Yes |
Recipe management |
Number of recipes | 5 |
Data records per recipe | 20 |
Entries per data record | 20 |
Size of internal recipe memory | 40 kbyte |
Recipe memory expandable | No |
Variables |
Number of variables per device | 250 |
Number of variables per screen | 30 |
Limit values | Yes |
Multiplexing | Yes |
Structures | No |
Arrays | Yes |
Images |
Number of configurable images | 50 |
Permanent window/default | Yes |
Global image | Yes |
Image selection by PLC | Yes |
Image number in the PLC | Yes |
Image objects |
Number of objects per image | 30 |
Text fields | Yes |
I/O fields | Yes |
Graphic I/O fields (graphics list) | Yes |
Symbolic I/O fields (text list) | Yes |
Date/time fields | Yes |
Switches | Yes |
Buttons | Yes |
Graphic display | Yes |
Icons | Yes |
Geometric objects | Yes |
Complex image objects |
Number of complex objects per screen | 5 |
Alarm view | Yes |
Trend view | Yes |
User view | Yes |
Status/control | No |
Sm@rtClient view | No |
Recipe view | Yes |
f(x) trend view | No |
System diagnostics view | No |
Media Player | No |
Bar graphs | Yes |
Sliders | No |
Pointer instruments | No |
Analog/digital clock | No |
Lists |
Number of text lists per project | 150 |
Number of entries per text list | 30 |
Number of graphics lists per project | 100 |
Number of entries per graphics list | 30 |
Archiving |
Number of archives per device | 0 |
Security |
Number of user groups | 50 |
Number of user rights | 32 |
Number of users | 50 |
Password export/import | No |
SIMATIC Logon | No |
Character sets |
Keyboard fonts | |
— US English | Yes |
Transfer (upload/download) |
MPI/PROFIBUS DP | No |
USB | No |
Ethernet | Yes |
using external storage medium | No |
Process coupling |
S7-1200 | Yes |
S7-1500 | Yes |
S7-200 | Yes |
S7-300/400 | Yes |
LOGO! | Yes |
WinAC | Yes |
SINUMERIK | No |
SIMOTION | No |
Allen Bradley (EtherNet/IP) | Yes |
Allen Bradley (DF1) | No |
Mitsubishi (MC TCP/IP) | Yes |
Mitsubishi (FX) | No |
OMRON (FINS TCP) | No |
OMRON (LINK/Multilink) | No |
Modicon (Modbus TCP/IP) | Yes |
Modicon (Modbus) | No |
Service tools/configuration aids |
Backup/Restore manually | Yes |
Backup/Restore automatically | No |
Simulation | Yes |
Device switchover | Yes |
Peripherals/Options |
Peripherals | |
Printer | No |
SIMATIC HMI MM memory card: Multi Media Card | No |
SIMATIC HMI SD memory card: Secure Digital memory card | No |
USB memory | No |
Mechanics/material |
Enclosure material (front) | |
Plastic | Yes |
Aluminum | No |
Stainless steel | No |
Dimensions |
Width of the housing front | 165 mm |
Height of housing front | 97 mm |
Mounting cutout, width | 149 mm |
Mounting cutout, height | 82 mm |
Overall depth | 30 mm |
Weights |
Weight without packaging | 0.25 kg |
Weight incl. packaging | 0.38 kg |
Other |
Note: | For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776 |
last modified: | 03/29/2019 |