SIMATIC PN/PN Coupler for deterministic data exchange between max.4 PN-Controller per subnet, also from subnet to subnet, PROFIsafe data exchange, I/O-, MSI-, MSO- and data record communication, redundant power supply, PN-connection via SIMATIC BusAdapter (BA), delivery w/o BusAdapter
General information
Firmware versionV4.2
FW update possibleYes
Product function
I&M dataYes; I&M0 to I&M3
Tool changerYes; Docking station and docking unit
Local coupling, IO dataYes
— Number of coupling modules16
— Number of coupling submodules per module4; 1x write, 3x read
Local coupling, data recordsYes
— Number of coupling modules16
— Number of coupling submodules per module4; 1x write, 3x read
— Record length, max.4 096 byte
— FIFO depth in storage mode8
Engineering with
STEP 7 TIA Portal configurable/integrated as of versionSTEP 7 V15.1 or higher
PROFINET as of GSD version/GSD revisionV2.3
Installation type/mounting
MountingMounting rail 7.5 mm and 15 mm
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
Mains/voltage failure stored energy time10 ms
Input current
Current consumption, max.360 mA; For 19.2 V input voltage at the right-hand supply terminal, including 2 plugged BA 2x LC
Inrush current, max.1.6 A
I²t0.031 A²·s
from supply voltage 1L+, max.320 mA; For 19.2 V input voltage at the left-hand supply terminal, including 2 plugged BA 2x LC
Power loss
Power loss, typ.4 W; For 24 V input voltage and 2 plugged BA 2x RJ45 If BusAdapters with an optical interface are plugged, there is an additional 750 mW per optical interface (3 W with 2 plugged BA 2x LC)
Address area
Address space per module
Address space per module, max.254 byte; max. 254 bytes of input data and 253 bytes of output data
Address space per station
Address space per station, max.1 440 byte; per input / output
Hardware configuration
Submodules
Number of submodules per station, max.116
Interfaces
Number of PROFINET interfaces2; One PROFINET interface per line side
With optical interfaceYes; Via SIMATIC BusAdapter
Supports protocol for PROFINET IO
automatic detection of transmission rateYes
Transmission rate, max.100 Mbit/s
1. Interface
Interface types
Number of ports2; via BusAdapter
integrated switchYes
BusAdapter (PROFINET)Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC
Protocols
PROFINET IO DeviceYes
Open IE communicationYes
Media redundancyYes; As MRP or MRPD client; max. 50 or 30 devices in the ring
2. Interface
Interface types
Number of ports2; via BusAdapter
integrated switchYes
Protocols
PROFINET IO DeviceYes
Open IE communicationYes
Media redundancyYes; As MRP or MRPD client; max. 50 or 30 devices in the ring
Interface types
RJ 45 (Ethernet)
Transmission procedurePROFINET with 100 Mbit/s full duplex (100BASE-TX)
10 MbpsNo
100 MbpsYes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
AutonegotiationYes
AutocrossingYes
Protocols
Supports protocol for PROFINET IOYes
Protocols (Ethernet)
TCP/IPYes
SNMPYes
LLDPYes
pingYes
ARPYes
PROFINET IO Device
Services
— Isochronous modeNo
— Open IE communicationYes
— IRTYes
— PROFIenergyNo
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.4; per line side
Redundancy mode
MRPYes
MRPDYes
PROFINET system redundancy (S2)Yes; NAP S2 acc. to IEC
Open IE communication
TCP/IPYes
SNMPYes
LLDPYes
Isochronous mode
Isochronous operation (application synchronized up to terminal)No; For operation on isochronous bus
Interrupts/diagnostics/status information
Status indicatorYes
AlarmsYes
Diagnostics functionYes; Parameterizable
Diagnostics indication LED
RUN LEDYes; Green LED
ERROR LEDYes; Red LED
MAINT LEDYes; yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Connection to network LINK (green)Yes; 2x green link LEDs on BusAdapter
Potential separation
between supply voltage and electronicsYes; to power input 2
between Ethernet and electronicsYes
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Network loading class3
Security levelAccording to Security Level 1 Test Cases V1.1.4
Ambient conditions
Ambient temperature during operation
min.0 °C
max.60 °C; = Tmax for horizontal installation; for vertical installation Tmax = 50 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeOn request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m
Mechanics/material
Strain reliefYes; Optional, for RJ45 and FC BusAdapter only
Dimensions
Width100 mm; Minimized with good handling
Height117 mm
Depth74 mm; with mounting rail
Weights
Weight, approx.200 g; without BusAdapter
last modified:03/12/2019