6ES7417-4XL04-0AB0
SIMATIC S7-400, CPU 417-4

From SIEMENS

SIMATIC S7-400, CPU 417-4 Central processing unit with: Work memory 20 MB (10 MB code; 10 MB data) 1st interface MPI 12 Mbit/s; 2nd interface PROFIBUS DP, 3rd/4th interface plug-in IFM module
General information
Product type designationCPU 417-4
Firmware versionV4.0
Engineering with
Programming packageSTEP 7 V5.2 SP1 HF3 or higher with HW update
CiR – Configuration in RUN
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte40 µs
Supply voltage
Rated value (DC)
24 V DCYes
Input current
from backplane bus 5 V DC, max.1.7 A
from backplane bus 24 V DC, max.Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface
Power loss
Power loss, typ.6 W
Memory
Work memory
integrated (for program)10 Mbyte
integrated (for data)10 Mbyte
expandableNo
Load memory
expandable FEPROMYes; with Memory Card (FLASH)
expandable FEPROM, max.64 Mbyte
integrated RAM, max.256 kbyte
expandable RAMYes; with Memory Card (RAM)
expandable RAM, max.16 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
Battery
Backup battery
Backup current, typ.600 µA
Backup current, max.1 810 µA
Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times
for bit operations, typ.0.03 µs
for word operations, typ.0.03 µs
for fixed point arithmetic, typ.0.03 µs
for floating point arithmetic, typ.0.09 µs
CPU-blocks
DB
Number, max.8 192; DB 0 reserved
Size, max.64 kbyte
FB
Number, max.6 144
Size, max.64 kbyte
FC
Number, max.6 144
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of time alarm OBs8
Number of delay alarm OBs4
Number of cyclic interrupt OBs9
Number of process alarm OBs8
Number of multicomputing OBs1
Nesting depth
per priority class24
additional within an error OB2
Counters, timers and their retentivity
S7 counter
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
S7 times
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetNo times retentive
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
Data areas and their retentivity
retentive data area in totalTotal working and load memory (with backup battery)
Flag
Number, max.16 kbyte
Retentivity availableYes; MB 0 to MB 16383
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Address area
I/O address area
Inputs16 kbyte
Outputs16 kbyte
Process image
Inputs, adjustable16 kbyte
Outputs, adjustable16 kbyte
Inputs, default1 024 byte
Outputs, default1 024 byte
consistent data, max.244 byte
Access to consistent data in process imageYes
Subprocess images
Number of subprocess images, max.15
Digital channels
Inputs131 072
— of which central131 072
Outputs131 072
— of which central131 072
Analog channels
Inputs8 192
— of which central8 192
Outputs8 192
— of which central8 192
Hardware configuration
Number of expansion units, max.21; of which 6 ER with K-bus
connectable OPs63 without message processing, 16 with message processing
MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.4; IM 463-2
Number of DP masters
integrated2
via CP10; via CP 443-5 Ext.
via IM 4674
Mixed mode IM + CP permittedNo; IM 467 cannot be used with CP 443-5 Ext., IM 467 cannot be used with CP 443-1 EX40 in PROFINET IO mode
via interface module2; IF 964-DP
Number of pluggable S5 modules (via adapter capsule in central device), max.6
Number of operable FMs and CPs (recommended)
FMLimited by number of slots and number of connections
CP, PtPCP 440: Limited by number of slots; CP 441: limited by number of connections
CP, LANLimited by number of slots and number of connections
PROFIBUS and Ethernet CPs14; incl. CP 443-5 Ext. and IM 467
Slots
required slots2
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Resolution1 ms
Deviation per day (buffered), max.Power off
Deviation per day (unbuffered), max.Power on
Operating hours counter
Number8
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
to IF 964 DPYes; as Master or Slave
1. Interface
PhysicsRS 485 / PROFIBUS
IsolatedYes
Number of connection resourcesMPI: 44, DP: 32
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
MPI
Number of connections44
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
PROFIBUS DP master
Number of connections, max.32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— EquidistanceYes
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Direct data exchange (slave-to-slave communication)Yes
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP slave
Transmission rate, max.12 Mbit/s
Address area, max.32
User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
PhysicsRS 485 / PROFIBUS
IsolatedYes
Number of connection resources32
Protocols
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
PROFIBUS DP master
Number of connections, max.32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.125
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— EquidistanceYes
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Direct data exchange (slave-to-slave communication)Yes
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP slave
Transmission rate, max.12 Mbit/s
Address area, max.32
User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— RoutingYes
Transfer memory
— Inputs244 byte
— Outputs244 byte
3. Interface
Interface typePluggable interface module (IF), technical data as for 2nd interface
Plug-in interface modulesIF 964-DP
4. Interface
Interface typePluggable interface module (IF), technical data as for 2nd interface
Plug-in interface modulesIF 964-DP
Isochronous mode
Isochronous operation (application synchronized up to terminal)Yes
EquidistanceYes
User data per isochronous slave, max.244 byte
shortest clock pulse1 ms
Communication functions
PG/OP communicationYes
Global data communication
supportedYes
Number of GD packets, transmitter, max.16
Number of GD packets, receiver, max.32
Size of GD packets, max.64 byte
Size of GD packet (of which consistent), max.1 variable
S7 basic communication
supportedYes; in MPI mode via: SFC X_SEND, X_RCV, X_GET and X_PUT; in DP master mode via: SFC I_GET and I_PUT
User data per job, max.76 byte
User data per job (of which consistent), max.1 variable
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 kbyte
User data per job (of which consistent), max.1 variable
S5 compatible communication
supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
User data per job, max.8 kbyte
Standard communication (FMS)
supportedYes; Via CP and loadable FB
Number of connections
overall64
usable for PG communication
— reserved for PG communication1
usable for OP communication
— reserved for OP communication1
S7 message functions
Number of login stations for message functions, max.16
Symbol-related messagesYes
Program alarmsYes
simultaneously active Alarm-S blocks, max.ALARM_S/SQ blocks or ALARM_D/DQ blocks
Alarm 8-blocksYes
Number of instances for alarm 8 and S7 communication blocks, max.Number of communication jobs for Alarm_8 blocks and for blocks for S7 Communication
Process control messagesYes
Number of messages
overall, max.1 024
in 100 ms grid, max.128
in 500 ms grid, max.512
in 1000 ms grid, max.1 024
Number of additional values
with 100 ms grid, max.1
with 500, 1000 ms grid, max.10
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
Forcing
ForcingYes
Diagnostic buffer
presentYes
Number of entries, max.3 200
— adjustableYes
— preset120
Configuration
Configuration software
STEP 7Yes
Programming
Nesting levels8
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Number of simultaneously active SFCs
— RDSYSST1 to 8
Know-how protection
User program protection/password protectionYes
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.1 070 g
last modified:03/13/2019